Price on Request
Easy and reliable technique to measure systemic blood pressure and cardiovascular parameters in rodents without invasive catheterization.
Item# |
Description |
|
---|---|---|
76-0173 |
Basic Unit for NIBP with RS-232 Serial Port. Cuff and Transducer must be ordered separately. (LE5001) |
|
76-0174 |
Standard Unit for NIBP with Memory and RS-232 Serial Port. Cuff and Transducer must be ordered separately. (LE5002) |
|
76-0175 |
Complete Unit for NIBP with Scheduled Data Acquisition (up to 12 Animals) Memory and RS-232 Serial Port. Cuff and Transducer must be ordered separately. (LE5007) |
|
76-0406 |
SEDACOM Software V2.0 |
|
76-0466 |
Panlab NIBP System Software for the traceability and graphical validation of the 76-0173, 76-0174 or 76-0175 data (NIBPCHART) |
|
76-0608 |
RS-232/USB Adapter for the SEDACOM software |
|
76-0177 |
Electronic Rat Simulator (LE5090) |
|
76-1137 |
Heater for Single Animal (LE5610A) |
|
76-0179 |
Automatic Heater and Scanner for Six Rats or Six Mice (LE5650-6) |
|
76-0432 |
Pulse Transducer & Cuff for Mice (Diameter 6 mm) (LE5160-MM) |
|
76-0012 |
Pulse Transducer & Cuff for Mice and Rats up to 150 Grams (LE5160M) |
|
76-0183 |
Holder, Mouse (15 to 25 gr) |
|
76-0184 |
Holder, Mouse (25 to 40 gr) |
|
76-0185 |
Holder, Rat (150gr) |
|
76-0186 |
Holder, Rat (250gr) |
|
76-0187 |
Holder, Rat (400gr) |
|
76-0188 |
Holder, Rat (500gr) |
|
76-0013 |
Pulse Transducer & Cuff for Rat (LE5160R) |
|
76-0014 |
Dog Pulse Transducer (18 mm Diameter) (LE5015) |
|
76-0015 |
Pressure Cuff for Dog Options (LE5012) |
|
76-0016 |
Set of 100 Spare Membranes for Rat Cuff (MB5160R) |
|
76-0017 |
Set of 10 Spare Membranes for Mouse Cuff (MB5160M) |
|
76-0018 |
Mouse Cuff (LE5180M) |
|
76-0019 |
Rat Cuff (LE5180R) |
|
The Panlab NIPB system provides an easy and reliable technique to measure systemic blood pressure and cardiovascular parameters in rodents without invasive catheterization.
The pulse signal level (heart rate) is continuously monitored on the LCD display while an internal pressure transducer is constantly measuring the current pressure applied on the cuff. Systolic and diastolic blood pressures are displayed after a series of automatic processes finish.
A warm environment is critical for accurate blood pressure measurement. For optimal conditions the Panlab Warming Chamber (76-1137) or the Automatic Heater & Scanner (76-0179) provides a comfortable heated environment. The requirement of a warm environment for the animals is critical for accurate blood pressure measurements. To provide adequate conditions for NIBP measurement, the system can be used in association with a warming chamber which provides a comfortable and heated environment necessary to produce peripheral vasodilatation and isolate the animal from external noise.
Key Features
Parameters Measured
Included Components
Basic Unit for NIBP 76-0173 (LE5001)
Standard Unit for NIBP 76-0174 (LE5002)
Complete Unit for NIBP 76-0175 (LE5007)
Accessories
*Pulse Transducer & Cuff and SEDACOM software must be ordered separately. Requires 76-0608 RS-232/USB adapter.
On Wing Tat Co. Ltd
20/F, Unit 1-5, Midas Plaza,
1 Tai Yau St.,San Po Kong,
Kowloon, Hong Kong