Non-Invasive Blood Pressure System for Rodents

Non-Invasive Blood Pressure System for Rodents

Brand: Harvard Apparatus
Product Code: -
Availability: In Stock

Price on Request

Easy and reliable technique to measure systemic blood pressure and cardiovascular parameters in rodents without invasive catheterization.

  • Total reliability to realize consecutive measurements on the same animal
  • Analog signal output for recording cuff pressure and pulse signals in a PC
  • Automated deflation driven separately for each animal (minimize tail lesions)
  • Automated cuff inflation/deflation at a very constant rate
  • The same system can be used for mouse/rat/dog
  • Real values provided (without any linear regression calculation)
  • Easily traceable data (using data acquisition software)
  • Parameters evaluated can be visualized on-line on the digital display

 

Item#

Description

 

76-0173

Basic Unit for NIBP with RS-232 Serial Port. Cuff and Transducer must be ordered separately. (LE5001)

 

76-0174

Standard Unit for NIBP with Memory and RS-232 Serial Port. Cuff and Transducer must be ordered separately. (LE5002)

 

76-0175

Complete Unit for NIBP with Scheduled Data Acquisition (up to 12 Animals) Memory and RS-232 Serial Port. Cuff and Transducer must be ordered separately. (LE5007)

 

76-0406

SEDACOM Software V2.0

 

76-0466

Panlab NIBP System Software for the traceability and graphical validation of the 76-0173, 76-0174 or 76-0175 data (NIBPCHART)

 

76-0608

RS-232/USB Adapter for the SEDACOM software

 

76-0177

Electronic Rat Simulator (LE5090)

 

76-1137

Heater for Single Animal (LE5610A)

 

76-0179

Automatic Heater and Scanner for Six Rats or Six Mice (LE5650-6)

 

76-0432

Pulse Transducer & Cuff for Mice (Diameter 6 mm) (LE5160-MM)

 

76-0012

Pulse Transducer & Cuff for Mice and Rats up to 150 Grams (LE5160M)

 

76-0183

Holder, Mouse (15 to 25 gr)

 

76-0184

Holder, Mouse (25 to 40 gr)

 

76-0185

Holder, Rat (150gr)

 

76-0186

Holder, Rat (250gr)

 

76-0187

Holder, Rat (400gr)

 

76-0188

Holder, Rat (500gr)

 

76-0013

Pulse Transducer & Cuff for Rat (LE5160R)

 

76-0014

Dog Pulse Transducer (18 mm Diameter) (LE5015)

 

76-0015

Pressure Cuff for Dog Options (LE5012)

 

76-0016

Set of 100 Spare Membranes for Rat Cuff (MB5160R)

 

76-0017

Set of 10 Spare Membranes for Mouse Cuff (MB5160M)

 

76-0018

Mouse Cuff (LE5180M)

 

76-0019

Rat Cuff (LE5180R)

 

 

ITEM LISTING

DETAILS

The Panlab NIPB system provides an easy and reliable technique to measure systemic blood pressure and cardiovascular parameters in rodents without invasive catheterization.

The pulse signal level (heart rate) is continuously monitored on the LCD display while an internal pressure transducer is constantly measuring the current pressure applied on the cuff. Systolic and diastolic blood pressures are displayed after a series of automatic processes finish.

A warm environment is critical for accurate blood pressure measurement. For optimal conditions the Panlab Warming Chamber (76-1137) or the Automatic Heater & Scanner (76-0179) provides a comfortable heated environment. The requirement of a warm environment for the animals is critical for accurate blood pressure measurements. To provide adequate conditions for NIBP measurement, the system can be used in association with a warming chamber which provides a comfortable and heated environment necessary to produce peripheral vasodilatation and isolate the animal from external noise. 

Key Features

  • Total reliability to realize consecutive measurements on the same animal
  • Analog signal output for recording cuff pressure and pulse signals in a PC
  • Automated deflation driven separately for each animal (minimize tail lesions)
  • Automated cuff inflation/deflation at a very constant rate
  • The same system can be used for mouse/rat/dog
  • Real values provided (without any linear regression calculation)
  • Easily traceable data (using data acquisition software)
  • Parameters evaluated can be visualized on-line on the digital display

Parameters Measured

  • Systolic blood pressure
  • Diastolic blood pressure
  • Mean blood pressure
  • Heart rate

Included Components

Basic Unit for NIBP 76-0173 (LE5001)

  • Control unit with LCD display
  • Pressure and pulse BNC analog signal output
  • RS-232 serial port
  • Cables
  • Spare fuses
  • Instruction manual

Standard Unit for NIBP 76-0174 (LE5002)

  • Includes all components of 76-0173 plus
  • Raw data internal memory (up to 4,000 successive trials)

Complete Unit for NIBP 76-0175 (LE5007)

  • Includes all components of 76-0174 plus
  • Statistical calculations (average, deviation, number of samples for all animals)
  • Connection to the Heater and Scanner device for automatic measurement of up to 12 animals

Accessories

  • SEDACOM Software*
  • Chart™ Software for monitoring of pressure and pulse wave signals
  • Single or multiple animal heating units
  • Pulse Transducer & Cuff*
  • Specimen holders

*Pulse Transducer & Cuff and SEDACOM software must be ordered separately. Requires 76-0608 RS-232/USB adapter.

 

 